Upon completion you should be able to.
Fire door assembly inspection checklist.
For fire doors and other opening protectives 2010 edition section 5 2 1 and nfpa 105 standard for smoke door assemblies and other opening protectives 2010 edition section 5 2.
Further inspection of the nfpa 101 code requirements reveals that paragraph 8 3 3 1 requires that openings in fire resistance rated assemblies e g fire barriers be protected by approved listed and labeled fire door assemblies in accordance with nfpa 80 regardless of the occupancy.
After years of inspecting fire doors most are out of compliance.
Take this online course to improve your ability to use nfpa 80.
Dai600 fire and egress door assembly inspection the newly updated dai600 curriculum is focused on understanding the role and responsibilities of the fire and egress door inspectors as well as interacting with the building owner and the authority having jurisdiction ahj.
Full compliance with the annual fire door assembly inspection and testing in accordance with 2010 nfpa 80 is required by january 1 2018.
All issues should be corrected immediately.
Fire damper commissioning fire smoke door inspection maintenance fire and smoke door repair and installation fire door labeling firestop survey installation above ceiling firestop survey fire barrier survey statement of conditions.
Inspect and test all rated fire door assemblies for items listed below and identify issues or concerns.
Fire door assembly inspection checklist the 2007 and 2010 editions of nfpa 80 standard for fire do ors and other opening protectives section 5 2 inspections require all fire doors to be inspect ed not less than annually.
Building owners and maintenance crews often consider a fire door compliant if it simply closes and latches shut.
Non rated door assemblies including corridor doors to patient care rooms and smoke barrier doors are not subject to the annual inspection and testing requirements of either nfpa 80 or nfpa 105.
Standard for fire doors and other opening protectives to locate interpret and correctly identify and apply the requirements for the inspection testing and maintenance of fire door assemblies.
This one hour self paced module is based on the 2016 edition of nfpa 80.
Life safety code lsc deficiencies associated with the annual inspection and testing of fire doors should be cited under k211 means of egress general.
It is paramount to ensure that the respective parties clearly.
But a latched door is not always fire code compliant.