The use of approved third party agencies to perform field re labeling for fire rated doors and frames is often a cost effective alternative to replacement of non compliant components while verifying the integrity of the opening.
Fire door certification label.
Advanced fire door training module.
For large scale buildings and property management companies fire door field inspection and labeling is a perpetual need and we have your.
The scheme has a variety of labels to suit the ratings and requirements of different door or doorset configurations.
Per nfpa 80 2 4 4 2 any and all doors to be equipped with fire exit hardware shall have the statement fire door to be equipped with fire exit hardware.
It is important to confirm that all new components have a label that.
After scheduling a visit based on the needs of your organization a guardian technician will come to your building to evaluate fire door assemblies including the door frame and kickplate.
Nfpa 80 provides specific guidance on what can and cannot be done to a rated door.
The proper labeling of fire rated assemblies is a vital part of life safety.
This course goes more in depth with the code requirements for different situations you encounter when doing the inspections.
The qai laboratory fire door certification label is the most widely recognized label in the industry.
Fire rated door field modifications.
Such technicians will analyze and review the material and construction of the three major components of the fire door assembly the door the frame and the kick plate and apply the appropriate time rated label as required.
Fire door field certification.
The advanced fire door training module is intended for the facility inspector that has completed the basic course and is very familiar with the nfpa code requirements.
The technician will apply the appropriate time rate labels 20 45 60 90 or 180 minutes to each component.
Apply the warnock hersey fire rating label when appropriate fire door certification.
For 20 minute fire doors not meeting the hose stream requirements.
Its correct specification fitting and maintenance are the responsibility of each and every person involved in the process.
Labels are required to have the words 20 minute without hose stream fire exit hardware.
A fire door is a vital safety device engineered to save lives and property.
Qai labels indicates compliance to appropriate national and local codes standards and requirements.
Field modifications of a fire rated door require specific knowledge of the codes and should be performed by a person qualified to work on rated openings.
The label is intact the door s certification and any modifications made to it can be traced.